AC Current

Resolution

Range

Slow

Medium

Fast

Burden Voltage*

10 mA

100 |JA

-

-

0.14 V

30 mA

-

1 jA

10 JA

0.45 V

100 mA

1 jA

10 JA

100 JA

1.4 V

10 A

100 jA

1 mA

10 mA

0.25 V

* Typical at full range

Accuracy

Accuracy

Range

Frequency

Slow

Medium

Fast

mA (To 100 mA)

20-50 Hz

2% + 100

2% + 10

7% + 2

mA (To 100 mA)

50 Hz - 10 kHz

0.5% + 100

0.5% + 10

0.8% + 2

mA (To 100 mA)

10 - 20 kHz

2% + 200

2% + 20

2% + 3

A (1-10 A)

20 - 50 Hz

2% + 100

2% + 10

7% + 2

A (1 - 10 A)

50 Hz - 2 kHz

1% + 100

1% + 10

1.3% + 2

A (0.5 to 1 A)

20 - 50 Hz

2% + 300

2% + 30

7% + 4

A (0.5 to 1 A)

50 Hz - 2 kHz

1% + 300

1% + 30

1.3% + 4

mA accuracy specifications apply within the following limits, based on reading rate:

Slow Reading Rate: Between 15,000 and 99,999 counts (full range) Medium Reading Rate: Between 1,500 and 30,000 counts (full range) Fast Reading Rate: Between 150 and 3,000 counts (full range)

Maximum Crest Factor 3.0

Maximum Input mA 300 mA dc or ac rms. Protected with a 500 mA, 250 V, IEC 127-sheet I, fast blow fuse and a 440 mA, 1000 V, fast blow fuse.

A 10 A dc or ac rms continuous, or 20 A dc or ac rms for 30 seconds maximum. Protected with a 11 A, 1000 V, 17,000 A interrupt rating, fast blow fuse.

Note

Resistance between the COM binding post and the meter's internal measuring circuits is approximately .003 W.

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.