3

J- Do not adjust

J- Do not adjust

Notes:

1. ( ): Items which need the confirmation when replaced.

2. When any adjustments 3.4.1. through 3.4.4. are necessary, please refer to "Preparation for Adjustments 5.4.1. through 3.4.4.".

3. When any adjustments 3.4.5. through 3.4.8., 3.4.11. and 3.4.12. are necessary, please refer to "Preparation for Adjustments 3.4.5. through 3.4.8., 3.4.11. and 3.4.12.".

3.1.1. The "FACTORY ADJUST" mode

All Electrical Adjustments are performed on the "FACTORY ADJUST" mode which is used remote control unit instead of variable resistor to control the adjustment value.

1. Connect a jumper wire between TP2017 and TP2018 on Main PWB for over 5 seconds to enter the "FACTORY ADJUST" mode.

2. Press the POWER button on remote control once.

3. While "Please press POWER button again to power off." is displayed, press the MENU button.

4. Press Aor~ button on remote control to select and press the ENTER button to set the item to be adjusted.