14 Applicable Signal

Quite a signals are used as the applicable signals in the preset mode (standard value) as shown in table 5-10. For the signals not fit to the preset modes, a user mode is provided.

In the preset modes, the applicable signals are based on the VESA standard, so the sample frequency (CLOCK adjustment in the panel menu) is not used, but the adjustment is allowed only in the user mode.

In the user mode, the signal line number is detected to allow the separate adjustment in the VGA system (basically effective for line number of 480/400/350 lines) and SVGA system (basically effective for line number of 600 lines).

In the user mode of SVGA system, the input signal is applicable to the plain display mode only in the XGA system (basically effective for line number of 768 lines) . That is, the signal is displayed.

Table 5-8 Applicable signal

Signal

Resolution

All

Frequency

Sync

Operation

Mode

Content

H

V

H

V

H

V

Clock

H/V

Check

Remarks

NTSC

NTSC

664

484

800

525

15.730

59.940

12.590

N/N

O

Video input

PAL

PAL

756

574

800

625

15.630

50.000

12.500

N/N

O

Video input

V60

VGA 60 Hz

640

480

800

525

31.470

59.940

25.175

N/N

O

V70

VGA 70 Hz

720

350

900

450

31.470

70.020

28.322

P/N

a

V70

VGA 70 Hz

720

400

900

450

31.470

70.020

28.322

N/P

a

V70

VGA 70 Hz

640

350

800

450

31.470

70.020

28.322

P/N

O

V70

VGA 70 Hz

640

400

800

450

31.470

70.020

28.322

N/P

O

V72

VGA 72 Hz

640

480

832

520

37.860

72.810

31.500

N/N

O

V75

VGA 75 Hz

640

480

840

500

37.500

75.000

31.500

N/N

O

V85

VGA 85 Hz

640

350

832

445

37.861

85.080

31.500

P/N

O

V85

VGA 85 Hz

640

400

832

445

37.861

85.080

31.500

N/P

O

V85

VGA 85 Hz

720

400

936

446

37.927

85.039

35.500

N/P

a

V85

VGA 85 Hz

640

480

832

509

43.269

85.008

36.000

N/N

O

M13

MAC-13"

640

480

864

525

35.000

66.670

30.240

N/N

O

24K

PC98

640

400

848

444

24.830

56.420

21.053

N/N

O

S56

SVGA 56 Hz

800

600

1024

625

35.160

56.250

36.000

N/N

O

S60

SVGA 60 Hz

800

600

1056

628

37.880

60.320

40.000

N/N

O

S72

SVGA 72 Hz

800

600

1040

666

48.080

72.190

50.000

N/N

O

S75

SVGA 75 Hz

800

600

1056

625

46.880

75.000

49.500

N/N

O

S85

SVGA 85 Hz

800

600

1048

631

53.674

85.061

56.250

N/N

O

M16

MAC-16"

832

624

1152

667

49.720

74.550

57.283

N/N

O

USHI

XGA 60 Hz

1024

768

1344

806

48.363

60.004

65.000

N/N

Plain display

USHI

XGA 70 Hz

1024

768

1328

806

54.476

70.069

75.000

N/N

Plain display

USHI

XGA 75 Hz

1024

768

1312

800

60.023

75.029

78.750

N/N

X

Plain display

USHI

XGA 85 Hz

1024

768

1376

808

68.677

84.997

94.500

N/N

X

Plain display

• In the sync column of table 5-8, P shows the positive • In the operation column, O shows a standard mode, D

polarity and N shows the negative polarity. shows pull-in mode, " shows plain display mode and

X shows the signal is out of correspondence.

0 0